ip prefix-list
provides the most powerful prefix based
filtering mechanism. In addition to access-list
functionality,
ip prefix-list
has prefix length range specification and
sequential number specification. You can add or delete prefix based
filters to arbitrary points of prefix-list using sequential number specification.
If no ip prefix-list is specified, it acts as permit. If ip prefix-list
is defined, and no match is found, default deny is applied.
You can create ip prefix-list
using above commands.
seq number can be set either automatically or manually. In the case that sequential numbers are set manually, the user may pick any number less than 4294967295. In the case that sequential number are set automatically, the sequential number will increase by a unit of five (5) per list. If a list with no specified sequential number is created after a list with a specified sequential number, the list will automatically pick the next multiple of five (5) as the list number. For example, if a list with number 2 already exists and a new list with no specified number is created, the next list will be numbered 5. If lists 2 and 7 already exist and a new list with no specified number is created, the new list will be numbered 10.
le
command specifies prefix length. The prefix list will be
applied if the prefix length is less than or equal to the le prefix length.
ge
command specifies prefix length. The prefix list will be
applied if the prefix length is greater than or equal to the ge prefix length.
Less than or equal to prefix numbers and greater than or equal to prefix numbers can be used together. The order of the le and ge commands does not matter.
If a prefix list with a different sequential number but with the exact same rules as a previous list is created, an error will result. However, in the case that the sequential number and the rules are exactly similar, no error will result.
If a list with the same sequential number as a previous list is created, the new list will overwrite the old list.
Matching of IP Prefix is performed from the smaller sequential number to the larger. The matching will stop once any rule has been applied.
In the case of no le or ge command, the prefix length must match exactly the length specified in the prefix list.